Precautions for use of emulsion tank
Precautions for use of the emulsion tank :
1 It must be ensured that all single piece devices are used in normal operation.
2 When sterilizing the filter, the steam pressure flowing through the air filter must not exceed 0.17 MPa, otherwise the filter element will be damaged and the filtering capacity will be lost.
3 During the fermentation process, ensure that the tank pressure does not exceed 0.17 MPa.
4 In the actual elimination process, when the jacket is preheated by steam, the inlet pressure must be controlled within the working pressure range of the equipment (not exceeding 0.2 MPa), otherwise the emulsion tank may be damaged.
5 When emptying and realizing, be sure to drain the remaining water from the emulsifying tank jacket. Otherwise, the inner cylinder of the emulsifying tank may be flattened, causing damage to the equipment; in the case of actual elimination, too much condensed water may cause the culture liquid to be diluted, thereby failing to meet the process requirements.
6 During the cooling process after the end of the air consumption and the end of the actual elimination, it is strictly forbidden to generate negative pressure inside the emulsion tank to avoid pollution and even damage the equipment.
7 During the fermentation process, the tank pressure should be maintained between 0.03 and 0.05 MPa to avoid contamination.
8 During each operation, the pressure in the air line must be kept larger than the tank pressure of the emulsion tank. Otherwise, the liquid in the emulsion tank will flow back into the filter, block the filter element or invalidate the filter.
9 If you encounter problems that you can't solve, please contact the company's after-sales service department directly. Do not forcefully disassemble or repair.